Datasheet, Volume 2 235
Processor Configuration Registers
2.16.9 FECTL_REG—Fault Event Control Register
This register specifies the fault event interrupt message control bits. The VTd
specification describes hardware handling of fault events.
B/D/F/Type: 0/0/0/DMIVC1REMAP
Address Offset: 38-3Bh
Reset Value: 80000000h
Access: RW, RO
Bit Attr
Reset
Value
Description
31 RW 1b
Interrupt Mask (IM)
0 = No masking of interrupt. When a interrupt condition is detected,
hardware issues an interrupt message (using the Fault Event Data &
Fault Event Address register values).
1 = This is the value on reset. Software may mask interrupt message
generation by setting this field. Hardware is prohibited from sending the
interrupt message when this field is set.
30 RO 0b
Interrupt Pending (IP)
Hardware sets the IP field whenever it detects an interrupt condition, which is
defined as:
When primary fault logging is active, an interrupt condition occurs when
hardware records a fault through one of the Fault Recording registers
and sets the PPF field in the Fault Status register.
When advanced fault logging is active, an interrupt condition occurs
when hardware records a fault in the first fault record (at index 0) of the
current fault log and sets the APF field in the Fault Status register.
Hardware detected error associated with the Invalidation Queue, setting
the IQE field in the Fault Status register.
Hardware detected invalid Device-IOTLB invalidation completion, setting
the ICE field in the Fault Status register.
Hardware detected Device-IOTLB invalidation completion time-out,
setting the ITE field in the Fault Status register.
If any of the status fields in the Fault Status register was already Set at the
time of setting any of these fields, it is not treated as a new interrupt
condition.
The IP field is kept Set by hardware while the interrupt message is held
pending. The interrupt message could be held pending due to the interrupt
mask (IM field) being Set or other transient hardware conditions.
The IP field is cleared by hardware as soon as the interrupt message pending
condition is serviced.
This could be due to either:
Hardware issuing the interrupt message due to either a change in the
transient hardware condition that caused the interrupt message to be
held pending, or due to software clearing the IM field.
Software servicing all the pending interrupt status fields in the Fault
Status register as follows.
When primary fault logging is active, software clearing the Fault
(F) field in all the Fault Recording registers with faults, causing the
PPF field in the Fault Status register to be evaluated as Clear.
Software clearing other status fields in the Fault Status register by
writing back the value read from the respective fields.
29:0 RO 00..00h Reserved
Vista de página 234
1 2 ... 230 231 232 233 234 235 236 237 238 239 240 ... 359 360

Comentários a estes Manuais

Sem comentários

Liebert Precision Cooling System DS podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Sprzęt komputerowy Liebert Precision Cooling System DS.
Dostarczamy 1 pdf podręczników Liebert Precision Cooling System DS do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Spis treści

User Manual

1

2

TABLE OF CONTENTS

3

SAVE THESE INSTRUCTIONS

11

2.0 COOLING CONFIGURATIONS

16

3.1 Room Preparation

17

Pre-Installation Guidelines

18

3.5 Operating Conditions

19

35"

22

33"

22

Dry Weight - lb. (kg)

23

Approximate

23

DPN000924

24

TOP VIEW

26

FRONT VIEW

26

DPN001013

28

24"

33

Supply air

37

26"

39

Top of Unit

40

DPN001196

43

SAFETY INFORMATION

45

Spreader Bars and Slings

46

Piano Jacks

46

Forklift

46

5.2.3 Removing Piano Jacks

48

DETAIL A

51

6.1 Required Equipment

52

6.3 Reassembly—Downflow Units

55

6.4 Reassembly Checklist

56

60-3/16"

57

(1529mm)

57

59-7/16"

60

(1509mm)

60

37"

61

6.5 Disassembly—Upflow Units

66

6.6 Reassembly—Upflow Unit

68

6.7 Reassembly Checklist

68

31-1/4"

69

45-13/16"

71

(1163mm)

71

7.0 ELECTRICAL CONNECTIONS

78

Electrical Connections

80

8.0 PIPING

82

INCORRECT

83

INCORRECTINCORRECT

83

General Guidelines

84

8.2 Refrigeration Piping

85

Fan Speed Control Piping

88

Fan Speed Charging

89

Lee-Temp Piping

90

Lee-Temp Charging

91

9.0 PIPING SCHEMATICS

92

For systems with drycoolers

94

CUSTOMER

95

HEAT REJECTION

95

LIEBERT DS UNIT

96

(and associated piping)

96

Piping Schematics

100

FRONT OF UNIT

101

Front View

101

Section A-A

101

DPN000803

101

Front of Unit

102

DPN000804

102

DPN000900

103

DPN000928

104

DPN000929

105

DPN000933

106

DPN001014

107

DPN001015

108

15-3/16"

109

FRONT SECTION VIEW

110

DPN001119

110

15-7/8"

111

FRONT SECTION VIEW OF UNIT

112

(Left Front Panel Not Shown)

112

TOP VIEW OF UNIT

112

Top View

113

Left Side Section View

113

Front Section View

113

FRONT SECTION VIEW OF UNIT

115

Front Of Unit

116

DPN001258

116

10.2 Electrical

117

10.3 Piping

117

10.4 Other

117

WARNING

118

12.0 MAINTENANCE

121

12.2 Blower Drive System

122

12.2.1 Upflow Motor Access

123

12.2.2 Belt Removal

123

Maintenance

124

Correct Switch Orientation

125

Incorrect Switch Orientation

125

DPN000996

125

12.4.1 Condensate Drain

126

12.4.2 Condensate Pump

126

12.7 Compressor

127

12.8 Compressor Replacement

128

12.10.1 Cleaning Instructions

129

12.11.3Drycooler Settings

131

AINTENANCE CHECKLIST

132

HVAC Maintenance Checklist

133

Glycol Pump

134

SL-18825_REV07_05-08

136





Więcej produktów i instrukcji dla Sprzęt komputerowy Liebert

Modele Rodzaj dokumentu
Extreme Density Chiller XDC Instrukcja Użytkownika   Liebert Extreme Density Chiller XDC User Manual, 64 strony
IntelliSlot OC-485 Instrukcja Użytkownika   Liebert IntelliSlot OC-485 User Manual, 2 strony
OpenComms Web Card Instrukcja Użytkownika   Liebert OpenComms Web Card User Manual, 2 strony
Cooling Modules XDH Instrukcja Użytkownika   Liebert Cooling Modules XDH User Manual, 36 strony
Refrigerant Distribution Unit XDP Instrukcja Użytkownika   Liebert Refrigerant Distribution Unit XDP User Manual, 40 strony
EM Instrukcja Użytkownika   Liebert EM User Manual, 48 strony
Integrated Cabinet Solutions Instrukcja Użytkownika   Liebert Integrated Cabinet Solutions User Manual, 2 strony
Extender/Adapter Instrukcja Użytkownika   Liebert Extender/Adapter User Manual, 8 strony
Overhead Precision Cooling and Humidity Control Mi Instrukcja Użytkownika   Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 User Manual, 12 strony