Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines 97
Figure 7-26. Positioning Solder on IHS
17. Measure the resistance from the thermocouple end wires again using the DMM
(refer to Section
D.5.1.step 2) to ensure the bead is still properly contacting the
IHS.
D.5.3 Solder Process
18. Make sure the thermocouple that monitors the Solder Block temperature is
positioned on the Heater block. Connect the thermocouple to a handheld meter to
monitor the heater block temperature
19. Verify the temperature of the Heater block station has reached 155° C ±5° C
before you proceed.
20. Connect the thermocouple for the device being soldered to a second hand held
meter to monitor IHS temperature during the solder process.