Intel CY80632007221AA Ficha Técnica Página 116

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 294
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 115
PCI Express*
Intel
®
Atom™ Processor E6xx Series Datasheet
116
8.2.1.7 CLS — Cache Line Size
8.2.1.8 HTYPE — Header Type
This register identifies the header layout of the configuration space. No physical
register exists at this location.
8.2.1.9 PBN — Primary Bus Number
This register identifies that this “virtual” Host-PCI Express* bridge is connected to PCI
bus #0.
8.2.1.10 SCBN — Secondary Bus Number
This register identifies the bus number assigned to the second bus side of the “virtual”
bridge, in other words, to the PCI Express* device. This number is programmed by the
PCI configuration software to allow mapping of configuration cycles to the PCI Express*
device.
Table 133. Offset 0Ch: CLS — Cache Line Size
Size: 8 bit Default: 00h Power Well: Core
Access
PCI Configuration B:D:F 0:23-26:0
Offset Start:
Offset End:
Ch
Ch
Bit Range Default Access Acronym Description
07 : 00 00h RW CLS
Cache Line Size: Implemented by PCI Express* devices as a read-write
field for legacy compatibility purposes but has no impact on any PCI
Express* device functionality.
Table 134. Offset 0Eh: HTYPE — Header Type
Size: 8 bit Default: 01h Power Well: Core
Access
PCI Configuration B:D:F 0:23-26:0
Offset Start:
Offset End:
Eh
Eh
Bit Range Default Access Acronym Description
07 : 00 01h RO HDR
Header Type Register: Returns 01h to indicate that this is a single
function device with a bridge header layout.
Table 135. Offset 18h:
PBN — Primary Bus Number
Size: 8 bit Default: 00h Power Well: Core
Access
PCI Configuration B:D:F 0:23-26:0
Offset Start:
Offset End:
18h
18h
Bit Range Default Access Acronym Description
07 : 00 00h RW PBN
Primary Bus Number: Configuration software typically programs this
field with the number of the bus on the primary side of the bridge. Since
the device is an internal device, its primary bus is always 0.
Vista de página 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 293 294

Comentários a estes Manuais

Sem comentários

Liebert Precision Cooling System DS podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Sprzęt komputerowy Liebert Precision Cooling System DS.
Dostarczamy 1 pdf podręczników Liebert Precision Cooling System DS do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Spis treści

User Manual

1

2

TABLE OF CONTENTS

3

SAVE THESE INSTRUCTIONS

11

2.0 COOLING CONFIGURATIONS

16

3.1 Room Preparation

17

Pre-Installation Guidelines

18

3.5 Operating Conditions

19

35"

22

33"

22

Dry Weight - lb. (kg)

23

Approximate

23

DPN000924

24

TOP VIEW

26

FRONT VIEW

26

DPN001013

28

24"

33

Supply air

37

26"

39

Top of Unit

40

DPN001196

43

SAFETY INFORMATION

45

Spreader Bars and Slings

46

Piano Jacks

46

Forklift

46

5.2.3 Removing Piano Jacks

48

DETAIL A

51

6.1 Required Equipment

52

6.3 Reassembly—Downflow Units

55

6.4 Reassembly Checklist

56

60-3/16"

57

(1529mm)

57

59-7/16"

60

(1509mm)

60

37"

61

6.5 Disassembly—Upflow Units

66

6.6 Reassembly—Upflow Unit

68

6.7 Reassembly Checklist

68

31-1/4"

69

45-13/16"

71

(1163mm)

71

7.0 ELECTRICAL CONNECTIONS

78

Electrical Connections

80

8.0 PIPING

82

INCORRECT

83

INCORRECTINCORRECT

83

General Guidelines

84

8.2 Refrigeration Piping

85

Fan Speed Control Piping

88

Fan Speed Charging

89

Lee-Temp Piping

90

Lee-Temp Charging

91

9.0 PIPING SCHEMATICS

92

For systems with drycoolers

94

CUSTOMER

95

HEAT REJECTION

95

LIEBERT DS UNIT

96

(and associated piping)

96

Piping Schematics

100

FRONT OF UNIT

101

Front View

101

Section A-A

101

DPN000803

101

Front of Unit

102

DPN000804

102

DPN000900

103

DPN000928

104

DPN000929

105

DPN000933

106

DPN001014

107

DPN001015

108

15-3/16"

109

FRONT SECTION VIEW

110

DPN001119

110

15-7/8"

111

FRONT SECTION VIEW OF UNIT

112

(Left Front Panel Not Shown)

112

TOP VIEW OF UNIT

112

Top View

113

Left Side Section View

113

Front Section View

113

FRONT SECTION VIEW OF UNIT

115

Front Of Unit

116

DPN001258

116

10.2 Electrical

117

10.3 Piping

117

10.4 Other

117

WARNING

118

12.0 MAINTENANCE

121

12.2 Blower Drive System

122

12.2.1 Upflow Motor Access

123

12.2.2 Belt Removal

123

Maintenance

124

Correct Switch Orientation

125

Incorrect Switch Orientation

125

DPN000996

125

12.4.1 Condensate Drain

126

12.4.2 Condensate Pump

126

12.7 Compressor

127

12.8 Compressor Replacement

128

12.10.1 Cleaning Instructions

129

12.11.3Drycooler Settings

131

AINTENANCE CHECKLIST

132

HVAC Maintenance Checklist

133

Glycol Pump

134

SL-18825_REV07_05-08

136





Więcej produktów i instrukcji dla Sprzęt komputerowy Liebert

Modele Rodzaj dokumentu
Extreme Density Chiller XDC Instrukcja Użytkownika   Liebert Extreme Density Chiller XDC User Manual, 64 strony
IntelliSlot OC-485 Instrukcja Użytkownika   Liebert IntelliSlot OC-485 User Manual, 2 strony
OpenComms Web Card Instrukcja Użytkownika   Liebert OpenComms Web Card User Manual, 2 strony
Cooling Modules XDH Instrukcja Użytkownika   Liebert Cooling Modules XDH User Manual, 36 strony
Refrigerant Distribution Unit XDP Instrukcja Użytkownika   Liebert Refrigerant Distribution Unit XDP User Manual, 40 strony
EM Instrukcja Użytkownika   Liebert EM User Manual, 48 strony
Integrated Cabinet Solutions Instrukcja Użytkownika   Liebert Integrated Cabinet Solutions User Manual, 2 strony
Extender/Adapter Instrukcja Użytkownika   Liebert Extender/Adapter User Manual, 8 strony
Overhead Precision Cooling and Humidity Control Mi Instrukcja Użytkownika   Liebert Overhead Precision Cooling and Humidity Control Mini-Mate2 User Manual, 12 strony