Intel SERVER SYSTEM SR2500AL Manual do Utilizador Página 143

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 142
Intel® Server System SR2500AL User’s Guide 121
In addition to the beep codes above, additional beep codes are provided if an Intel
®
Remote Management Module is installed. The Intel
®
Remote Management Module
provides the following additional beep codes.
Table 10. Error Beep Codes Generated by Intel
®
Remote Management
Module
Number of
Beeps
Reason for Beeps and Action to Take
1 Control panel CMOS clear has been initiated.
1-5-1-1 Processor failure. Reseat or replace the failed processor.
1-5-2-1 No processor is installed or the CPU 1 socket is empty. Reseat or replace
the failed processor.
1-5-2-3 Processor configuration error or CPU 1 socket is empty. Reseat or replace
the failed processor. In a two-processor system, make sure the processors
are identical.
1-5-2-4 Front-side bus select configuration error.
1-5-4-2 DC power unexpectedly lost.
1-5-4-3 Chipset control failure.
1-5-4-4 Power control failure.
Vista de página 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 209 210

Comentários a estes Manuais

Sem comentários