Intel® Solid-State Drive DC S3500
April 2013 Product Specification
Order Number: 328860-001US 7
Table 3. Random Read/Write IOPS Consistency
Random 4 KB Read
(up to)
2
Random 4 KB Write (up to)
Random 8 KB Read
(up to)
3
Random 8 KB Write
(up to)
Notes: 1. Performance measured using Iometer* with Queue Depth 32. Measurements are performed on a full Logical Block
Address (LBA) span of the drive.
2. 4 KB = 4,096 bytes
3. 8 KB = 8,192 bytes
4. Performance consistency measured using Iometer* based on Random 4KB QD=32 workload, measured as the (IOPS
in the 99.9th percentile slowest 1-second interval)/(average IOPS during the test). Measurements are performed on a
full Logical Block Address (LBA) span of the drive once the workload has reached steady state, including all background
activities required for normal operation and data reliability
Table 4. Sequential Read and Write Bandwidth
Sequential Read (SATA
6Gb/s)
1
Sequential Write
(SATA
6Gb/s)
1
Notes: 1. Performance measured using Iometer* with 128 KB (131,072 bytes) of transfer size with Queue Depth 32.
80GB (2.5/1.8”), 120GB, 160GB, 240GB (2.5”/1.8”),
300GB, 400GB (1.8”), 480GB, 600 GB
Latency
1
(TYP)
Read
Write
Power On to Ready
2