Intel SGI Altix 450 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Manuais de software Intel SGI Altix 450. Intel SGI Altix 450 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - 450 System User’s Guide

SGI® Altix® 450 System User’s Guide Document Number 007-4857-002

Página 2

x 007-4857-002ContentsPhysical Specifications . . . . . . . . . . . . . . . . .

Página 3 - Record of Revision

78 007-4857-0023: System OverviewOptional System ComponentsAvailability of optional components for the SGI 450 systems may vary based on new product i

Página 4

007-4857-002 79Chapter 44. System ControlThis chapter describes the interaction and functions of system controllers in the following sections:• “Level

Página 5

80 007-4857-0024: System ControlFigure 4-1 SGI Altix 450 System Control Network (Example)Levels of System ControlThe system control network configurat

Página 6

System Controller Interaction007-4857-002 81The system controller is designed into all IRUs. An Ethernet connection directly from the IRU to a local

Página 7 - 007-4857-002 vii

82 007-4857-0024: System ControlL1 Controller FunctionsThe following list summarizes the control and monitoring functions that the L1 controller perfo

Página 8

Ethernet Switch007-4857-002 83The front panel display contains the following items:• 2 x 12 character liquid crystal display (LCD). The display ident

Página 9 - 007-4857-002 ix

84 007-4857-0024: System ControlConsole Hardware RequirementsThe console type and how these console types are connected to the Altix 450 servers is de

Página 10 - Contents

Operating the L1007-4857-002 85application that is always running on the system controller. When the enclosure is connected to a LAN via the L2 host

Página 11 - List of Figures

86 007-4857-0024: System Control• “Viewing Information, Warnings, and Error Messages” on page 94Viewing System Configuration (from an IRU’s Perspectiv

Página 12

Operating the L1007-4857-002 87Commands can be targeted to other L1s by preceding the command with a rack and slot:001c01-L1> 1.11 version The com

Página 13

List of Figures007-4857-002 xiList of FiguresFigure 1-1 30-amp Single-phase Power Receptacle for North American Sites . . . 9Figure 1-2

Página 14

88 007-4857-0024: System ControlL1 Console SelectionIf the system contains more than one IRU and a serial connection is utilized for the console, the

Página 15 - List of Tables

L2 Operation007-4857-002 89001c01-L1> entering console mode 001c01 console, <CTRL-T> to escape to L1no response from 001c01 junk bus console

Página 16

90 007-4857-0024: System ControlTo see if the L2 is running (it will be if the LAN cable is plugged in and the cable is connected to an active LAN). A

Página 17 - About This Guide

L2 Operation007-4857-002 91Once the L2 is running, you can telnet to the L2, or use an optional SGIconsole. After the connection to the L2 controller

Página 18 - Chapter Descriptions

92 007-4857-0024: System Controlb is the enclosure type.ss is the slot location of the enclosure.p is the partition of the enclosure (not present if t

Página 19 - Related Publications

L2 Operation007-4857-002 93To target individual blades in an IRU use the following syntax:olympic-101-L2> 1.11 b1 power downExecuting the above co

Página 20

94 007-4857-0024: System ControlL2> r 2-4,7 <L1 command> This is a one-time destination.Command InterpretationSome L2 commands are the same a

Página 21 - Product Support

L2 Operation007-4857-002 95To power on or power off a specific IRU, specify a current destination:L2> r 2 s 5 power up L2>To power on or power

Página 22 - Reader Comments

96 007-4857-0024: System ControlCtrl+T escaping to L2 system controllerL2> l2 L2 command processor engaged, <CTRL_D> for console mode.L2>C

Página 23 - 1. System Installation

L2 Operation007-4857-002 97• Subchannel 3C specifies Blade 3, CPU C.• Subchannel console0 Blade 0 console subchannel.• Subchannel console1 Blade 1 co

Página 24 - System Installation Overview

xii 007-4857-002List of FiguresFigure 2-4 2D Graphics Card Location in IA2 Blade . . . . . . . . . 59Figure 3-1 S

Página 25 - Safety Precautions

98 007-4857-0024: System ControlGenerally, the L2 will track the correct IRU rack, slot, blade, and subchannel for system console input and no user se

Página 26 - Warning:

Upgrading L1 Firmware007-4857-002 99Upgrading L1 FirmwareThe L1 firmware is currently distributed as part of the snxsc_firmware package. To determine

Página 27 - Safety Measures

100 007-4857-0024: System ControlYou can update individual IRUs by replacing all with a rack and slot number:$> /usr/cpu/firmware/sysco/flashsc --1

Página 28 - Installing a Rack

007-4857-002 101Chapter 55. Rack InformationThis chapter describes the physical characteristics of the tall (42U) and short (20U) Altix racks in the f

Página 29 - Tools Required

102 007-4857-0025: Rack InformationAltix 42U and 20U Rack FeaturesThe Altix racks (shown in Figure 5-1 and Figure 5-2) have the following features and

Página 30 - Power Receptacle Verification

Altix 42U and 20U Rack Features007-4857-002 103Figure 5-1 Tall (42U) Altix Rack and Front Lock

Página 31 - 007-4857-002 9

104 007-4857-0025: Rack InformationFigure 5-2 Short (20U) Altix Rack (Rear View)Technical SpecificationsTable 5-1 lists the technical specifications o

Página 32 - 1: System Installation

Technical Specifications007-4857-002 105Depth 40.9 in. (103.9 cm)Weight (full) 750 lb (340 kg)Table 5-2 Short Altix Rack Technical Specifications (co

Página 34 - 12 007-4857-002

007-4857-002 107Chapter 66. Maintenance and Upgrade ProceduresThis chapter provides information about installing or removing components from your SGI

Página 35 - 007-4857-002 13

List of Figures007-4857-002 xiiiFigure 6-23 Seating the Card in the Slot . . . . . . . . . . . . .1

Página 36 - Inspecting the Shipping Crate

108 007-4857-0026: Maintenance and Upgrade ProceduresPreparing the System for Maintenance or UpgradeTo prepare the system for maintenance, follow thes

Página 37 - 007-4857-002 15

Installing or Removing Internal Parts007-4857-002 109Installing or Removing Internal PartsCaution: The components inside the system are extremely sen

Página 38 - 16 007-4857-002

110 007-4857-0026: Maintenance and Upgrade ProceduresReplacing IRU ComponentsWhile the individual rack units (IRUs) are not considered end-user replac

Página 39 - 007-4857-002 17

Replacing IRU Components007-4857-002 111Figure 6-1 Removing the L1 Controller PanelReplace the system control panel using the following steps:1. Posit

Página 40 - 18 007-4857-002

112 007-4857-0026: Maintenance and Upgrade Procedures3. Be careful not to snag the ribbon cable while replacing the panel.4. Use the T10 torx driver t

Página 41 - 007-4857-002 19

Replacing IRU Components007-4857-002 113Removing or Adding IRU Power SuppliesUnder most circumstances a single power supply in an IRU can be replaced

Página 42 - COMPACT COMPACT

114 007-4857-0026: Maintenance and Upgrade Procedures4. Install the new power supply with the retention latch at the top of the supply. 5. Slide the p

Página 43 - O) position

Replacing IRU Components007-4857-002 1153. A line will be added to the L1 system controller’s log file indicating the fan warning.4. If ESP is used, a

Página 44 - 22 007-4857-002

116 007-4857-0026: Maintenance and Upgrade ProceduresFigure 6-6 Removing a Fan From the IRU3. Slide a new blower assembly completely into the open slo

Página 45

Replacing IRU Components007-4857-002 117Figure 6-7 Replacing an IRU Fan BATighten screw

Página 47 - 6th hole

118 007-4857-0026: Maintenance and Upgrade ProceduresRemoving or Replacing a System Blade From the IRUThe blades installed in your SGI Altix 450 can g

Página 48

Replacing IRU Components007-4857-002 119Figure 6-8 Removing a Compute/Memory Blade From the IRU COMPACTinsideTMBinsideTMCOMPACTinsideTMAC

Página 49 - 10-32 x 1/2-inch screws

120 007-4857-0026: Maintenance and Upgrade ProceduresFigure 6-9 Replacing a Compute/Memory Blade in the IRUCOMPACTinsideTMinsideTMBCCOMPACTAinsideTM

Página 50 - 28 007-4857-002

Replacing IRU Components007-4857-002 121Memory DIMM Group Placement and GuidelinesMemory is contained on cards that are referred to as DIMMs (dual inl

Página 51

122 007-4857-0026: Maintenance and Upgrade ProceduresFigure 6-10 DIMM Group Locations DiagramLeft bus Y DIMM 2 (DIMM location 5)Left bus Y DIMM 1 (DIM

Página 52 - 30 007-4857-002

Replacing IRU Components007-4857-002 123Figure 6-11 DIMM Memory Slot Location ExampleRemove and Replace the DVD DriveUse the following steps to remove

Página 53 - 007-4857-002 31

124 007-4857-0026: Maintenance and Upgrade Procedures8. Slide the new DVD drive assembly into the IA blade housing.9. Connect the DVD power and data c

Página 54 - 32 007-4857-002

Replacing IRU Components007-4857-002 125Figure 6-12 DVD Removal from IA BladeBCDAPower connectorData connectorDVD retentionscrewCOMPACTCOMPACTCOMPACT

Página 55 - 007-4857-002 33

126 007-4857-0026: Maintenance and Upgrade ProceduresFigure 6-13 DVD Drive Replacement in the IA BladeCOMPACTCOMPACTBPower connectorData connectorAC D

Página 56 - 34 007-4857-002

Overview of PCI Express Operation007-4857-002 127Overview of PCI Express OperationThis section provides a brief overview of the new PCI Express (PCIe)

Página 57 - 007-4857-002 35

List of Tables007-4857-002 xvList of TablesTable 1-1 Installation Tools. . . . . . . . . . . . . .

Página 58 - Connecting the System Console

128 007-4857-0026: Maintenance and Upgrade Procedures1”. SGI Altix 450 technology uses an x16 connector (64 wires) or “by 16” in PCI Express card slot

Página 59 - 007-4857-002 37

Adding or Replacing PCI/PCI-X Cards007-4857-002 129Caution: To protect the PCI cards from ESD damage, SGI recommends that you use a grounding wrist s

Página 60 - Operating Your System

130 007-4857-0026: Maintenance and Upgrade ProceduresFigure 6-16 Extracting the Carrier Metal Filler Plate

Página 61 - 007-4857-002 39

Adding or Replacing PCI/PCI-X Cards007-4857-002 131Note: If you are adding or replacing a half-height PCI card, skip ahead to step 6.5. If the full-h

Página 62

132 007-4857-0026: Maintenance and Upgrade Proceduresc. Mount the card in the carrier, (see Figure 6-18) and ensure the following occurs:– The card co

Página 63 - 007-4857-002 41

Adding or Replacing PCI/PCI-X Cards007-4857-002 1336. To install a half-height PCI card in a carrier, follow these steps:a. Remove the two screws from

Página 64

134 007-4857-0026: Maintenance and Upgrade Procedurese. Place the PCI card bracket so that the screw holes of the bracket align with the empty screw h

Página 65 - Powering Off Manually

Adding or Replacing PCI/PCI-X Cards007-4857-002 1357. Insert the carrier-mounted PCI card into the vacant slot, using the slot guide, as shown in Figu

Página 66 - L1 Front Panel Controls

136 007-4857-0026: Maintenance and Upgrade ProceduresAdd or Remove a PCI Card in Base IA BladesTo add or replace a PCI card in the base IA blade (base

Página 67 - Operating the L1 Controller

Adding or Replacing PCI/PCI-X Cards007-4857-002 137Figure 6-25 Replacing the IA Blade PCI Access Door8. Replace the PCI card access door by installing

Página 69 - 2. Operation Procedures

138 007-4857-0026: Maintenance and Upgrade ProceduresInstalling or Replacing a Disk Drive in the IA BladeThe IA/IA2 blade (base I/O) in an IRU has two

Página 70

Installing or Replacing a Disk Drive in the IA Blade007-4857-002 139Removing a System Disk DriveBefore you remove a disk drive, you must power off the

Página 71 - System Controller Network

140 007-4857-0026: Maintenance and Upgrade ProceduresInstalling a System Disk DriveBefore you install a disk drive, you must power off the IRU that ho

Página 72 - Console Connections

Installing or Replacing a Disk Drive in the IA Blade007-4857-002 141Figure 6-28 Replacing a Disk Drive COMPACTCOMPACT

Página 74 - Preparing to Power On

007-4857-002 143Chapter 77. Troubleshooting and DiagnosticsThis chapter provides the following sections to help you troubleshoot your system:• “Troubl

Página 75 - 007-4857-002 53

144 007-4857-0027: Troubleshooting and DiagnosticsTroubleshooting ChartTable 7-1 lists recommended actions for problems that can occur. To solve probl

Página 76

L1 Controller Error Messages007-4857-002 145L1 Controller Error MessagesTable 7-2 lists error messages that the L1 controller generates and displays o

Página 77

146 007-4857-0027: Troubleshooting and DiagnosticsTemperature messages: low alt.ATTN: <temp sensor description> advisory temperature reached @ x

Página 78 - 2: Operation Procedures

LED Status Indicators007-4857-002 147LED Status IndicatorsThere are a number of LEDs on the front of the IRUs that can help you detect, identify and p

Página 79 - Monitoring Your Server

007-4857-002 xviiAbout This GuideThis guide provides an overview of the installation, architecture, general operation and descriptions of the major co

Página 80 - 2D Graphics Video Interface

148 007-4857-0027: Troubleshooting and DiagnosticsCompute/Memory Blade LEDsEach compute/memory blade installed in an IRU has a total of eight LED indi

Página 81 - Altix 450 series server:

SGI Electronic Support007-4857-002 149Figure 7-1 Compute Blade Status LED LocationsSGI Electronic Support SGI Electronic Support provides system suppo

Página 82 - I/O Blade Overview

150 007-4857-0027: Troubleshooting and DiagnosticsFigure 7-2 Full Support SequencePage or e-mailalert5SupportfolioOnlineView the casesolutions2e-mail6

Página 83

SGI Electronic Support007-4857-002 151The sequence of events can be described as follows:1. Embedded Support Partner (ESP) monitors your system 24 hou

Página 84

The following three components compose the integrated SGI Electronic Support system:SGI Embedded Support Partner (ESP) is a set of tools and utilities

Página 85

007-4857-002 153Appendix AA. Technical Specifications and PinoutsThis appendix contains technical specification information about your system, as foll

Página 86

154 007-4857-002A: Technical Specifications and PinoutsPhysical SpecificationsTable A-2 shows the physical specifications of the Altix 450 system in a

Página 87

Physical Specifications007-4857-002 155Table A-3 Altix 450 Short Rack System Physical SpecificationsFeature SpecificationDimensions for a single short

Página 88

156 007-4857-002A: Technical Specifications and PinoutsEnvironmental SpecificationsTable A-4 lists the environmental specifications of the 42U rack sy

Página 89 - 3. System Overview

Power Specifications007-4857-002 157Power SpecificationsTable A-6 shows the power specifications for the system.Heat dissipationAltix 450 29.86 kBTU/

Página 90 - System Models

xviii 007-4857-002About This Guide• Using the ESI/ops panel (operating panel) on optional mass storage bricks. See the user’s guide for your optional

Página 91 - 007-4857-002 69

158 007-4857-002A: Technical Specifications and PinoutsI/O Port SpecificationsThis section contains specifications and port pinout information for the

Página 92 - System Architecture

I/O Port Specifications007-4857-002 159Ethernet PortThe system auto-selects the Ethernet port speed and type (duplex vs. half-duplex) when the server

Página 93 - 007-4857-002 71

160 007-4857-002A: Technical Specifications and PinoutsSerial PortsThe IRU modules have 9-pin serial interface connectors. These ports are for console

Página 94 - System Features

I/O Port Specifications007-4857-002 161Table A-8 shows pinout assignments for the 9-pin male DB-9 connector.Table A-8 Serial Port Pinout Pin Assignmen

Página 95 - Distributed Shared I/O

162 007-4857-002A: Technical Specifications and PinoutsExternal SAS/SATA Port Connector Figure A-3 shows the connector pin locations for the external

Página 96 - 3: System Overview

I/O Port Specifications007-4857-002 163USB Type A ConnectorFigure A-4 shows the USB type A connector provided on the base I/O that supports general US

Página 98 - System Components

007-4857-002 165Appendix BB. Safety Information and Regulatory SpecificationsThis appendix provides safety information and regulatory specifications f

Página 99 - Rack Numbering

166 007-4857-002B: Safety Information and Regulatory Specifications9. Do not attempt to service this product yourself except as noted in this guide. O

Página 100 - Optional System Components

Regulatory Specifications007-4857-002 167Regulatory SpecificationsThe following topics are covered in this section:• “CMN Number” on page 167• “CE Not

Página 101 - 4. System Control

Related Publications007-4857-002 xixRelated PublicationsThe following SGI documents are relevant to the Altix 450 series system:• SGI L1 and L2 Contro

Página 102 - Levels of System Control

168 007-4857-002B: Safety Information and Regulatory SpecificationsElectromagnetic EmissionsThis section provides the contents of electromagnetic emis

Página 103 - L1 Controller

Regulatory Specifications007-4857-002 169Industry Canada Notice (Canada Only)This Class A digital apparatus meets all requirements of the Canadian Int

Página 104 - L1 Front Panel Display

170 007-4857-002B: Safety Information and Regulatory SpecificationsShielded CablesThis SGI system is FCC-compliant under test conditions that include

Página 105 - Ethernet Switch

Regulatory Specifications007-4857-002 171Laser Compliance StatementsThe DVD drive in this computer is a Class 1 laser product. The DVD drive’s classif

Página 106 - Operating the L1

172 007-4857-002B: Safety Information and Regulatory SpecificationsLithium Battery StatementsWarning: If a lithium battery is a soldered part, only q

Página 107 - 001c01-L1>

007-4857-002 173IndexAAltix serverillustration, 69Altix serversmonitoring locations, 57Bbattery statements, 172block diagramIRU, 71Ccache coherenc

Página 108 - Command Targeting

174 007-4857-002Indexfan RPM level, 114front panel displayL1 controller, 82front panel LEDs, 44Iinformation, warning, and error messagesviewing in

Página 109 - Console Mode from L1

007-4857-002 175Indexracks, 77PPCI and PCI-X cardsinstallation procedurePCI and PCI-X card installation, 128PCIe slots, 60physical specificationsAl

Página 110 - L1 Console Selection

176 007-4857-002IndexUunpack a tall rack, 18unpack and move the short rack, 16upgrading L1 firmware, 99USB type Aconnector pin assignments, 163VVG

Página 111 - L2 Operation

CONTRIBUTORSWritten by Mark Schwenden Illustrated by Chrystie Danzer Production by Mark SchwendenEngineering contributions by Rich Altmaier, Steve Bow

Página 112

xx 007-4857-002About This GuideReferences in the documentation to these pages include the name of the command and the section number in which the comm

Página 113 - Viewing System Configuration

Conventions007-4857-002 xxiConventionsThe following conventions are used throughout this document:Product SupportSGI provides a comprehensive product

Página 114 - Setting Command Targeting

xxii 007-4857-002About This GuideReader CommentsIf you have comments about the technical accuracy, content, or organization of this document, contact

Página 115

007-4857-002 1Chapter 11. System InstallationThis chapter describes how to unpack and install your Altix 450 system. Specifically, the following topi

Página 116

2 007-4857-0021: System InstallationSystem Installation Overview In this chapter, different installation instructions are provided for different type

Página 117 - Console Mode from the L2

Safety Precautions007-4857-002 3• If you have ordered either a single- or dual-IRU system that you intend to install on a table top, follow the instr

Página 118 - Console Selection

4 007-4857-0021: System InstallationHazard StatementsDuring the installation of your Altix 450 system, be alert for hazard advisory statements with i

Página 119

Safety Precautions007-4857-002 5Safety MeasuresObserve the following safety measures when you install the system:• Use caution when you remove the sy

Página 120 - L1 Mode From L2

6 007-4857-0021: System InstallationInstalling a RackThis section describes how to install a rack that already has your system IRUs rackmounted and c

Página 121 - Upgrading L1 Firmware

Installing a Rack007-4857-002 7Tools RequiredTable 1-1 lists the tools that you need to complete the installation.Table 1-1 Installation ToolsTool Pa

Página 122 - 4: System Control

007-4857-002 iiiRecord of RevisionVersion Description-001 August 2006,First release-002 March 2007,Engineering updates to cover RAID 1, DVD-R/W, 2D gr

Página 123 - 5. Rack Information

8 007-4857-0021: System InstallationPower Receptacle VerificationEnsure that a qualified technician installs the correct power receptacles. Your Alti

Página 124 - 5: Rack Information

Installing a Rack007-4857-002 9Figure 1-1 30-amp Single-phase Power Receptacle for North American SitesGroundsocketSocket XReceptacleSocket YPower co

Página 125 - 007-4857-002 103

10 007-4857-0021: System InstallationFor international sites, follow these steps to ensure that a single-phase power receptacle is properly wired: 1.

Página 126 - Technical Specifications

Installing a Rack007-4857-002 11Figure 1-2 32-amp Single-phase Power Plug for International SitesPower cordconnectorSocket 1(line)Ground socketSocket

Página 127 - Weight (full) 750 lb (340 kg)

12 007-4857-0021: System InstallationUnloading and Moving System EquipmentYour Altix 450 system arrives at the site in a pallet-mounted cardboard shi

Página 128

Installing a Rack007-4857-002 13If your site does not have a loading dock, arrange for a forklift to unload the system from the transportation vehicl

Página 129 - 007-4857-002 107

14 007-4857-0021: System InstallationFigure 1-4 shows the lift openings and dimensions of a short rack shipping crate. This figure also shows where t

Página 130

Installing a Rack007-4857-002 15Transporting the Shipping CrateUse a pallet jack with forks that are 48 in. (122 cm) long or longer to transport the

Página 131 - Component Procedure

16 007-4857-0021: System InstallationRemoving a Short Rack from the Shipping CrateWarning: Be careful when you unpack and move the short rack system

Página 132 - Replacing IRU Components

Installing a Rack007-4857-002 17Figure 1-5 Removing a Short Rack from the Shipping CrateFoamcushionCardboardcover134a 4b4c52RampRear mountingbracketF

Página 134 - 112 007-4857-002

18 007-4857-0021: System InstallationUnpacking and Installing the Tall RackWarning: In its maximum configuration, a (42U) tall rack system weighs ap

Página 135 - 007-4857-002 113

Installing a Rack007-4857-002 19Figure 1-6 Removing a Tall Rack from the Shipping CrateCOMPACT124BungeecushionCOMPACT COMPACTCOMPACT COMPACT35COMPACT

Página 136 - ATTN: Fan (number) warning

20 007-4857-0021: System InstallationFigure 1-7 Reattaching the Tall Rack DoorsCOMPACT COMPACTCOMPACT COMPACT

Página 137 - 007-4857-002 115

Installing a Rack007-4857-002 21Positioning and Leveling Racks Caution: To avoid ESD damage to the electronic components, be sure to position the ra

Página 138 - 116 007-4857-002

22 007-4857-0021: System InstallationFigure 1-9 Seismic Tie-down Attachment PointsUnpacking and Inspecting ModulesThis section describes how to unpac

Página 139 - 007-4857-002 117

Unpacking and Inspecting Modules007-4857-002 23Firmly connect the base module of the IRU to the fan module using these steps:1. Align the rear connec

Página 140 - 118 007-4857-002

24 007-4857-0021: System InstallationInstalling the IRUs in a RackThis section describes how to install the IRUs that compose an Altix 450 system in

Página 141 - 007-4857-002 119

Installing the IRUs in a Rack007-4857-002 25Determining Where to Attach Rails in a RackThe base IRU, and any additional IRUs, each require five units

Página 142 - 120 007-4857-002

26 007-4857-0021: System InstallationRackmounting IRUs with Shelf RailsThis section describes how to rackmount an IRU using shelf rails. The shelf ra

Página 143 - 007-4857-002 121

Installing the IRUs in a Rack007-4857-002 27Note: Even with the blades, power supplies and fan module disconnected, the IRU’s base unit is heavy. Al

Página 144 - 122 007-4857-002

Contents007-4857-002 vContentsList of Figures . . . . . . . . . . . . . . . . .

Página 145 - 007-4857-002 123

28 007-4857-0021: System InstallationRemoving a Rackmounted IRU ModuleTo remove an IRU that is already mounted in a rack, follow these steps:1. Power

Página 146 - 124 007-4857-002

NUMAlink Cabling the System IRUs007-4857-002 29NUMAlink Cabling the System IRUsSome configurations of an Altix 450 system will consist of either two

Página 147 - 007-4857-002 125

30 007-4857-0021: System InstallationFigure 1-14 NUMAlink Cabling an IRU to an Additional IRUTo connect two Altix 450 compute modules to each other w

Página 148 - 126 007-4857-002

Cabling the System IRUs to a Power Source007-4857-002 31The console output should indicate that the processors and memory on both IRU modules have be

Página 149 - 007-4857-002 127

32 007-4857-0021: System InstallationFigure 1-15 Power-Supply Connectors on the IRU ModuleFigure 1-16 shows the connecting of a dual-IRU system locat

Página 150 - Connector

Cabling the System IRUs to a Power Source007-4857-002 33Figure 1-16 Connecting an Unracked IRU System to a Power SourcePowerdistributionunit (PDU)Pow

Página 151 - 007-4857-002 129

34 007-4857-0021: System InstallationConnecting System Modules to a Rack Power SourceIf your Altix 450 system is shipped from SGI in a rack, there wi

Página 152 - 130 007-4857-002

Cabling the System IRUs to a Power Source007-4857-002 35Figure 1-18 shows an example of the optional three-phase PDU available in tall racks only. Fi

Página 153 - 007-4857-002 131

36 007-4857-0021: System InstallationConnecting the System ConsoleThis section explains how to attach and establish a connection between a system con

Página 154 - 132 007-4857-002

Connecting the System Console007-4857-002 37Figure 1-19 Location of the L1 Console PortConsole portReset buttonEthernet portinsideTML1 controllerpane

Página 155 - 007-4857-002 133

vi 007-4857-002ContentsInstalling a Rack . . . . . . . . . . . . . . . . . .

Página 156 - 134 007-4857-002

38 007-4857-0021: System InstallationOperating Your SystemThis section describes how to operate your Altix 450 system, as follows:• “Powering the Sys

Página 157 - 007-4857-002 135

Operating Your System007-4857-002 39Powering On With Optional System Console and L1/L2 ControllerTo power on and boot your system using the system co

Página 158 - 136 007-4857-002

40 007-4857-0021: System Installation4. Verify that all of the L1 controllers display “L1 running.” If any L1 controllers are not running, contact yo

Página 159 - 007-4857-002 137

Operating Your System007-4857-002 41Powering On Manually or With L1 ConsoleIf your system does not have a a local system console, you can manually po

Página 160 - 138 007-4857-002

42 007-4857-0021: System InstallationPowering Off at the System ConsoleTo power off your system using the system console, follow these steps:Caution:

Página 161 - Removing a System Disk Drive

Operating Your System007-4857-002 43Powering Off ManuallyTo power off your system manually, follow these steps:Caution: If you power off the system

Página 162 - 140 007-4857-002

44 007-4857-0021: System InstallationL1 Front Panel ControlsThe L1 front panel of the Altix 450 IRU provides the following control features, as shown

Página 163 - 007-4857-002 141

Operating Your System007-4857-002 45Note: If your system includes an optional storage module, see the user’s guide that comes with the product for o

Página 164

46 007-4857-0021: System Installationescaping to L1 system controller001c01-L1> l1 L1 command processor engaged, <CTRL-D> for console mode.0

Página 165 - Chapter 7

007-4857-002 47Chapter 22. Operation ProceduresThis chapter explains how to operate your new system in the following sections:• “Precautions” on page

Página 166 - Troubleshooting Chart

Contents007-4857-002 vii2. Operation Procedures . . . . . . . . . . . . . . . . .

Página 167 - L1 Controller Error Messages

48 007-4857-0022: Operation ProceduresSafety PrecautionsWarning: Before operating or servicing any part of this product, read the “Safety Information

Página 168

System Controller Network007-4857-002 49System Controller NetworkAll Altix 450 enclosures contain an embedded microprocessor board and display assembl

Página 169 - LED Status Indicators

50 007-4857-0022: Operation ProceduresConsole ConnectionsA console is defined as a connection to the system that provides access to the system control

Página 170 - Compute/Memory Blade LEDs

Communicating with the System Controller007-4857-002 51Communicating with the System ControllerOnce a connection to the console is established, the us

Página 171 - SGI Electronic Support

52 007-4857-0022: Operation ProceduresPreparing to Power OnTo prepare to power on your system, follow these steps:1. Check to ensure that the cabling

Página 172 - 150 007-4857-002

Powering the System On and Off007-4857-002 53Figure 2-2 Single-Phase Rack PDU Circuit Breaker SwitchesPowerdistributionunit (PDU)PowersourceOn/off swi

Página 173 - 007-4857-002 151

54 007-4857-0022: Operation ProceduresPowering On and Off at the ConsoleThe power-on and off procedure at a console varies with your server setup, as

Página 174

Powering the System On and Off007-4857-002 55oo1c01-L1> * power down(* indicates all)From the L1 prompt, display the system configuration informati

Página 175 - System-level Specifications

56 007-4857-0022: Operation ProceduresPowering-On and Off From the L2Commands issued at the L2 prompt are typically sent to all NUMAlink connected IRU

Página 176 - Physical Specifications

Monitoring Your Server007-4857-002 57Monitoring Your ServerYou can monitor your Altix 450 server from the following sources:• On the L1 controller’s d

Página 177 - Feature Specification

viii 007-4857-002ContentsSystem Components . . . . . . . . . . . . . . . . . .

Página 178 - Environmental Specifications

58 007-4857-0022: Operation Procedures2D Graphics Video InterfaceIf your system was ordered in January 2007 or later, it may come equipped with an opt

Página 179 - Power Specifications

Installing Optional Components007-4857-002 59Figure 2-4 2D Graphics Card Location in IA2 (base I/O) BladeInstalling Optional ComponentsBesides adding

Página 180 - I/O Port Specifications

60 007-4857-0022: Operation ProceduresWarning: You can add or replace only the items listed in this section. For your safety and for the protection o

Página 181 - Ethernet Port

Installing Optional Components007-4857-002 61Adding or Removing Disk DrivesThe IA/IA2 blade (base I/O blade) within the IRU supports the system boot f

Página 182 - Serial Ports

Select a device: [1-1 or 0 to quit] 1 1. Identify firmware, BIOS, and/or FCode 2. Download firmware (update the FLASH) 4. Download/erase BIOS and/

Página 183 - Pin Assignment Description

Installing Optional Components007-4857-002 63 1. Identify firmware, BIOS, and/or FCode 2. Download firmware (update the FLASH) 4. Download/erase BI

Página 184

64 007-4857-0022: Operation Procedures B___T___L Type Vendor Product Rev Disk Blocks Disk MB 1. 0 0 0 Disk SGI

Página 185 - USB Type A Connector

Installing Optional Components007-4857-002 65fs0:\> reset...EFI Boot Manager ver 1.10 [14.62]Partition 0: Enabled Disabl

Página 186

66 007-4857-0022: Operation Procedures1 volume is active, 2 physical disks are activeVolume 0 is Bus 0 Target 0, Type IM (Integrated Mirroring) Volum

Página 187 - Safety Information

007-4857-002 67Chapter 33. System OverviewThis chapter provides an overview of the physical and architectural aspects of your SGI Altix 450 system. Th

Página 188 - 166 007-4857-002

Contents007-4857-002 ixAltix 42U and 20U Rack Features . . . . . . . . . . . . . . . .

Página 189 - Regulatory Specifications

68 007-4857-0023: System OverviewFigure 3-1 SGI Altix 450 System (Short Rack)System ModelsThe basic enclosure within the Altix 450 system is the 5U hi

Página 190 - Electromagnetic Emissions

System Models007-4857-002 69Figure 3-2 SGI Altix 450 Server System (Tall Rack)You can also add additional PCI expansion blades or RAID and non-RAID d

Página 191 - Equipment Regulations

70 007-4857-0023: System OverviewFigure 3-3 Blade, IRU and Rack ComponentsSystem ArchitectureThe Altix 450 computer system is based on a distributed s

Página 192 - Shielded Cables

System Architecture007-4857-002 71interface. The SHub ASIC memory interface enables any processor in the system to access the memory of all processor

Página 193 - Laser Compliance Statements

72 007-4857-0023: System OverviewSystem FeaturesThe main features of the Altix 450 series server systems are introduced in the following sections:• “M

Página 194 - Lithium Battery Statements

System Features007-4857-002 73Memory latency is the amount of time required for a processor to retrieve data from memory. Memory latency is lowest wh

Página 195

74 007-4857-0023: System OverviewNon-uniform Memory Access (NUMA)In DSM systems, memory is physically located at various distances from the processors

Página 196 - 174 007-4857-002

System Features007-4857-002 75• Power-on and boot:– Automatic testing occurs after you power on the system. (These power-on self-tests or POSTs are a

Página 197

76 007-4857-0023: System OverviewSystem ComponentsThe Altix 450 series system features the following major components:• 20U rack. The “short” rack is

Página 198 - 176 007-4857-002

System Components007-4857-002 77Figure 3-5 Altix 450 IRU System Components ExampleBay (Unit) NumberingBays in the racks are numbered using standard u

Comentários a estes Manuais

Sem comentários