Environmental Specifications Intel® Server System SR1600UR TPS
56 Intel order number E45725-010 Revision 1.8
10. Environmental Specifications
10.1 System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 44. System Environmental Limits Summary
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating
-40°C to +70°C
90%, non-condensing at 35°C
Acoustic noise Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23
Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged
Trapezoidal, 25 g, velocity change 136 inches/second (≧40 lbs to < 80 lbs)
Non-palletized free fall in height 24 inches (
≧
5 Hz to 500 Hz, 2.20 g RMS random
Half sine, 2 g peak, 11 milliseconds
+/-15 KV except I/O port +/- 8 KV per Intel
®
Environmental test specification
System Cooling
2550 BTU/hour
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
10.2 Serviceability and Availability
The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes, including diagnosis of
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
The following table defines the maximum time needed by a trained field service technician to
perform the listed system maintenance procedures, after diagnosing the system and identifying
the failed component.
Table 45. Time Estimate for System Maintenance Procedures
Remove and replace hard disk drive
Remove and replace power supply module
Remove and replace system fan
Remove and replace backplane board
Remove and replace control panel module
Remove and replace server board
Comentários a estes Manuais