Intel R2000BB4GS9 Especificações Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 66
Hardware Installations and Upgrades
Intel
®
Server System R2000BB Service Guide 55
3.
Figure 83. Replacing a system fan
Replacing the Backplane
Replacing the 3.5” Hard Drive Backplane
Removing the 3.5” Hard Drive Backplane:
1. Remove all hot-swap drive carriers, regardless of whether or not a drive is installed in the
carrier. Disconnect all cables from the backplane.
2. Remove the six screws to release the hard drive cage (see letter “A”).
3. Slide the hard drive cage out of the server chass, the clip will fall out automatically (see letter
“B”).
Figure 84. Removing 3.5hard drive backplane remove the hard drive cage
4. Remove the screw at the rear of the backplane (see letter “C”);