Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Environmental Specifications
Revision 2.0 37
Intel order number G17455-004
11. Environmental Specifications
11.1 System Level Environmental Limits
The following table defines the system-level operating and non-operating environmental limits.
Table 30. System Environmental Limits Summary
Parameter Limits
Operating Temperature
+10° C to +35° C with the maximum rate of change not to exceed 10° C per hour
Non-Operating
Temperature
-40° C to +70° C
Non-Operating Humidity
90%, non-condensing at 35° C
Acoustic noise Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 +/-
2 degrees C)
Shock, operating Half sine, 2 g peak, 11 msec
Shock, unpackaged
Trapezoidal, 25 g, velocity change 136 inches/sec (≧40 lbs to > 80 lbs)
Shock, packaged
Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs)
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating Half sine, 2 g peak, 11 mSec
ESD +/-12kV for air discharge and 8K for contact
System Cooling
Requirement in BTU/Hr
1660 BTU/hour
Vista de página 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 66 67

Comentários a estes Manuais

Sem comentários

EdgeStar Sušičky uživatelské příručky

Seznam produktů EdgeStar Sušičky obsahuje 2 uživatelské příručky pro 2 modelů. Všechny uživatelské příručky pdf jsou k dispozici ke stažení nebo prohlížení online.

Klepnutím na abecedu níže přejděte na úplný seznam modelů začínajících tímto písmenem

Modely Typ Dokumentu
CENELEC CW1200
Uživatelský manuál   EdgeStar CENELEC CW1200 User's Manual, 24 stránky
Model CW 2200
Uživatelský manuál   EdgeStar Model CW 2200 User's Manual, 24 stránky