650 UPS
Specifications
Hardware
To install and use the J2 UPS module:
1: Remove the power supply adapter form the base of the unit.
2: Install the UPS module where the power supply was mounted.
3: Connect the power output jack of the UPS to the power in jack of the unit.
4: Connect the Serial cable of the UPS to the serial port you wish to use. *
5: Connect the power supply adapter to the UPS power in jack.
6: Connect the power supply adapter to the mains power. **
7: Configure the Windows UPS drive as shown.
Picture to be added here
* The serial port connection is not needed for Windows CE.
** The mains power should be applied for 3 hours to fully charge the batteries. The unit
may be running during this time but will take longer to charge.
Batteries Run Time 2 Hours for the standard 650. Run time will vary
depending on the processor used and application load
Power In 19 Volts DC
Power Out 13-16.8 Volts DC, 7.2 amps maximum
Data Interface RS232 DB9 connector
Batteries Type 2 – 4 18650 cell Li-Ion pack with protection circuit
Battery Life 300 full discharge cycles
Charge Time 3 hours
Charger Type Smart Microcontroller based
Software XP Standard Generic UPS driver / J2 Smart UPS driver
Size 6” x 3.1” x 1.7” (152mm x 79mm x 43mm)