Intel SR2500 Ficha Técnica Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 115
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
Intel® Server System SR2500AL Cooling Subsystem
Revision – 1.00
Intel order number D31980-004
23
Table 15. Nonredundant Fan Header Assignment
Fan ID Mid-plane Fan Header Name
Fan #1 - CPU1 cooling FAN_2
Fan #2 - CPU2 cooling FAN_4
Fan #3 - PCI Cooling FAN_6
3.2 Redundant System Fan Module
TP02102
Figure 17. Fan Module Assembly
Table 16 Redundant Cooling Zones
Each 10-pin fan connector provides power and ground, PWM control, tachometer output, a fan
present detection signal, and a fault LED signal allowing it to be monitored independently by
server management software. The following table provides the pin-out and description for the
connectors on each fan.
Fan Cooling
Zone
Description of greatest cooling influence
System Fan #1 & #2 CPU1 Primary cooling for CPU1 and memory
System Fan #2 & #3 CPU2 Primary cooling for hard drives hard drives 4 and
5, CPU2, the BNB, and the low profile PCI cards
System Fan #5 & #6 PCI Primary cooling for hard drives 2 and 3, Full
Height PCI cards, PXH and IOP80333 chipset
Power Supply Fans 2
fans per module
Power
Supply
Primary cooling for hard drives 0 and 1, and the
power supply module(s)
Vista de página 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 114 115

Comentários a estes Manuais

Sem comentários